Full Range of Model Specifications.

Hazardgard comes in a range of sizes and capacities. Click on the model number for detailed installation information. Take a look.

We’ve also included definitions of some common air conditioning terms. Contact us if you would like us to add one that we’ve missed.

Moisture Removal
Measured in pints per hour, this rates the air conditioner’s dehumidifying capability.
4.0–8.0 pints/24 hours
Air Circulation (CFM)
The amount of air that moves past a stationary point in one minute. Measured in cubic feet per minute.
360-425 ft3/min
Cooling Capacity
Air conditioner capacities are rated in Btu per hour. This is the measurement used to match your cooling or heating needs with an air conditioner. Btu stands for British Thermal Unit, which is the amount of heat needed to raise the temperature of one pound of water by one degree Fahrenheit.
14500–24000 Btu/hr
EER
The Energy Efficiency Ratio measures how efficiently an air conditioner will operate when the outdoor temperature is 95°. The ratio is calculated by dividing the cooling capacity (Btu/h) by the power needed to run the unit (watts). The higher the EER, the more efficient the air conditioner and the less costly it is to operate.
8.5–9.7

Individual Specifications

Click model number for detailed specifications.

Hazardgard 60 Hertz (North America)

Model Cooling Capacity
(Btu/hr)
Heating Capacity
(Btu/hr)
EER Energy Star Qualified Unit Height Unit Width
SH15M30A 14500/14000 n/a 9.7/9.7 15 15/16" 25 15/16"
  • Unit Dimensions

    Height
    15 15/16"
    Width
    25 15/16"
    Depth
    27 3/8"
  • Window Dimensions

    Min. height
    16 1/2"
    Min. width
    27 7/8"
    Max. width
    42
  • In-Wall Installation

    Opening height
    16 3/16"
    Opening width
    26 3/16"
    Max. wall depth
    6"

Additional Measurement Information

Depth J Box to Louvers
6
Min. Extension Into Room
3 1/16"
Min. Extension Outside
16 15/16"

Detailed Electrical Information

Voltage/Hertz/Phase
230/208/60/1
Circuit Rating Breaker or T-D Fuse
250V-15A
Cooling Amps
6.9/7.5
Cooling Watts
1495/1443
Air Circulation
375 cubic feet per minute
Air Direction Controls
8-way
Moisture Removal
4.0 pints/24 hours
Net Weight
140 lbs
Shipping Weight
167 lbs
Suggested Retail Price
$3,359
SH20M30A 20000/19000 n/a 9.4/9.4 17 15/16" 25 15/16"
  • Unit Dimensions

    Height
    17 15/16"
    Width
    25 15/16"
    Depth
    27 3/8"
  • Window Dimensions

    Min. height
    18 1/2"
    Min. width
    27 7/8"
    Max. width
    42
  • In-Wall Installation

    Opening height
    18 3/16"
    Opening width
    26 3/16"
    Max. wall depth
    6"

Additional Measurement Information

Depth J Box to Louvers
6
Min. Extension Into Room
3 1/16"
Min. Extension Outside
16 15/16"

Detailed Electrical Information

Voltage/Hertz/Phase
230/208/60/1
Circuit Rating Breaker or T-D Fuse
250V-15A
Cooling Amps
8.7/9.6
Cooling Watts
2074/2021
Air Circulation
375 cubic feet per minute
Air Direction Controls
8-way
Moisture Removal
5.5 pints/24 hours
Net Weight
166 lbs
Shipping Weight
170 lbs
Suggested Retail Price
$3,679
SH24M20 24000/23700 n/a 8.8/8.5 17 15/16" 25 15/16"
  • Unit Dimensions

    Height
    17 15/16"
    Width
    25 15/16"
    Depth
  • Window Dimensions

    Min. height
    Min. width
    Max. width
  • In-Wall Installation

    Opening height
    n/a
    Opening width
    n/a
    Max. wall depth
    n/a

Additional Measurement Information

Depth J Box to Louvers
Min. Extension Into Room
Min. Extension Outside

Detailed Electrical Information

Voltage/Hertz/Phase
Circuit Rating Breaker or T-D Fuse
Cooling Amps
13.2
Cooling Watts
2412
Air Circulation
385 cubic feet per minute
Air Direction Controls
Moisture Removal
7.0 pints/24 hours
Net Weight
lbs
Shipping Weight
lbs
Suggested Retail Price
$3.899

Hazardgard 50 Hertz (International)

Model Cooling Capacity
(Btu/hr)
Heating Capacity
(Btu/hr)
EER Energy Star Qualified Unit Height Unit Width
SH20M50A 19500/19100 n/a 9.0/9.0 17 15/16" 25 15/16"
  • Unit Dimensions

    Height
    17 15/16"
    Width
    25 15/16"
    Depth
  • Window Dimensions

    Min. height
    Min. width
    Max. width
  • In-Wall Installation

    Opening height
    n/a
    Opening width
    n/a
    Max. wall depth
    n/a

Additional Measurement Information

Depth J Box to Louvers
Min. Extension Into Room
Min. Extension Outside

Detailed Electrical Information

Voltage/Hertz/Phase
Circuit Rating Breaker or T-D Fuse
Cooling Amps
Cooling Watts
Air Circulation
cubic feet per minute
Air Direction Controls
Moisture Removal
pints/24 hours
Net Weight
lbs
Shipping Weight
lbs
Suggested Retail Price
$3,779
SH24M20 20500 n/a 8.5 17 15/16" 25 15/16"
  • Unit Dimensions

    Height
    17 15/16"
    Width
    25 15/16"
    Depth
  • Window Dimensions

    Min. height
    Min. width
    Max. width
  • In-Wall Installation

    Opening height
    n/a
    Opening width
    n/a
    Max. wall depth
    n/a

Additional Measurement Information

Depth J Box to Louvers
Min. Extension Into Room
Min. Extension Outside

Detailed Electrical Information

Voltage/Hertz/Phase
Circuit Rating Breaker or T-D Fuse
Cooling Amps
12.6/13.5
Cooling Watts
Air Circulation
360 cubic feet per minute
Air Direction Controls
Moisture Removal
8.0 pints/24 hours
Net Weight
lbs
Shipping Weight
lbs
Suggested Retail Price
$3,899

Energy Guide Label