Full Range of Model Specifications.

Vert-I-Pak comes in a range of sizes and capacities. Click on the model number for detailed installation information. Take a look.

We’ve also included definitions of some common air conditioning terms. Contact us if you would like us to add one that we’ve missed.

Air Circulation (CFM)
The amount of air that moves past a stationary point in one minute. Measured in cubic feet per minute.
375–610 ft3/min
EER
The Energy Efficiency Ratio measures how efficiently an air conditioner will operate when the outdoor temperature is 95°. The ratio is calculated by dividing the cooling capacity (Btu/h) by the power needed to run the unit (watts). The higher the EER, the more efficient the air conditioner and the less costly it is to operate.
9.0–9.8
Cooling Capacity
Air conditioner capacities are rated in Btu per hour. This is the measurement used to match your cooling or heating needs with an air conditioner. Btu stands for British Thermal Unit, which is the amount of heat needed to raise the temperature of one pound of water by one degree Fahrenheit.
9000–23000 Btu/hr
Heating Capacity
Air conditioner capacities are rated in Btu per hour. This is the measurement used to match your cooling or heating needs with an air conditioner. Btu stands for British Thermal Unit, which is the amount of heat needed to raise the temperature of one pound of water by one degree Fahrenheit.
8000–20000 Btu/hr

Individual Specifications

2012 Vert-I-Pak Models

Model Cooling Capacity
(Btu/hr)
Heating Capacity
(Btu/hr)
EER Energy Star Qualified Min. Extension Into Room Min. Extension Outside
VHA09K 9200/8900 8500/8000 9.8/9.8 32" 23"
  • Unit Dimensions

    Height
    32"
    Width
    23"
    Depth
    23"

Detailed Electrical Information

Volts Rated
230/208
Cooling Amps
4.1/4.3
Amps (locked rotor)
18.5 amps
Amps (full load)
3.6 amps
Cooling Watts
939/908
Heating Amps
3.6/3.9
Heating Watts
830/811
Plug Face (NEMA #)
Power Cord Length
ft.
Air Circulation
375 cubic feet per minute
Est. Yearly Operating Costs
n/a
Moisture Removal
2.2 pints/hr
Net Weight
114 lbs
Shipping Weight
125 lbs
Suggested Retail Price
$3,259
Indoor CFM, High
n/a
Indoor CFM, Med
n/a
Indoor CFM, Low
375
VEA09K 9400/9000 n/a 9.8/9.8 32" 23"
  • Unit Dimensions

    Height
    32"
    Width
    23"
    Depth
    23"

Detailed Electrical Information

Volts Rated
230/208
Cooling Amps
4.2/4.4
Amps (locked rotor)
22 amps
Amps (full load)
3.7 amps
Cooling Watts
959/918
Heating Amps
n/a
Heating Watts
n/a
Plug Face (NEMA #)
Power Cord Length
ft.
Air Circulation
375 cubic feet per minute
Est. Yearly Operating Costs
n/a
Moisture Removal
2.2 pints/hr
Net Weight
114 lbs
Shipping Weight
125 lbs
Suggested Retail Price
$2,804
Indoor CFM, High
n/a
Indoor CFM, Med
n/a
Indoor CFM, Low
375
VEA12K 11500/11200 n/a 9.8/9.8 32" 23"
  • Unit Dimensions

    Height
    32"
    Width
    23"
    Depth
    23"

Detailed Electrical Information

Volts Rated
230/208
Cooling Amps
5.2/5.4
Amps (locked rotor)
30 amps
Amps (full load)
4.5 amps
Cooling Watts
1173/1143
Heating Amps
n/a
Heating Watts
n/a
Plug Face (NEMA #)
Power Cord Length
ft.
Air Circulation
350 cubic feet per minute
Est. Yearly Operating Costs
n/a
Moisture Removal
3.2 pints/hr
Net Weight
124 lbs
Shipping Weight
135 lbs
Suggested Retail Price
$2,942
Indoor CFM, High
n/a
Indoor CFM, Med
n/a
Indoor CFM, Low
350
VHA12K 11500/11200 10800/10600 9.7/9.7 32" 23"
  • Unit Dimensions

    Height
    32"
    Width
    23"
    Depth
    23"

Detailed Electrical Information

Volts Rated
230/208
Cooling Amps
5.3/5.5
Amps (locked rotor)
26 amps
Amps (full load)
5.0 amps
Cooling Watts
1186/1155
Heating Amps
4.6/4.9
Heating Watts
1055/1035
Plug Face (NEMA #)
Power Cord Length
ft.
Air Circulation
375 cubic feet per minute
Est. Yearly Operating Costs
n/a
Moisture Removal
3.2 pints/hr
Net Weight
125 lbs
Shipping Weight
135 lbs
Suggested Retail Price
$3,365
Indoor CFM, High
375
Indoor CFM, Med
n/a
Indoor CFM, Low
n/a
VEA18K 17000/16500 n/a 9.0/9.0 32" 23"
  • Unit Dimensions

    Height
    32"
    Width
    23"
    Depth
    23"

Detailed Electrical Information

Volts Rated
230/208
Cooling Amps
8.1/8.6
Amps (locked rotor)
42 amps
Amps (full load)
7.8 amps
Cooling Watts
1889/1833
Heating Amps
n/a
Heating Watts
n/a
Plug Face (NEMA #)
Power Cord Length
ft.
Air Circulation
450 cubic feet per minute
Est. Yearly Operating Costs
n/a
Moisture Removal
6 pints/hr
Net Weight
144 lbs
Shipping Weight
155 lbs
Suggested Retail Price
$3,365
Indoor CFM, High
450
Indoor CFM, Med
n/a
Indoor CFM, Low
n/a
VHA18K 17000/16800 16000/15000 9.1/9.1 32" 23"
  • Unit Dimensions

    Height
    32"
    Width
    23"
    Depth
    23"

Detailed Electrical Information

Volts Rated
230/208
Cooling Amps
8.2/8.6
Amps (locked rotor)
42 amps
Amps (full load)
7.8 amps
Cooling Watts
1868/1846
Heating Amps
7.5/8.2
Heating Watts
1560/1540
Plug Face (NEMA #)
Power Cord Length
ft.
Air Circulation
450 cubic feet per minute
Est. Yearly Operating Costs
n/a
Moisture Removal
6 pints/hr
Net Weight
144 lbs
Shipping Weight
155 lbs
Suggested Retail Price
$3,858
Indoor CFM, High
450
Indoor CFM, Med
n/a
Indoor CFM, Low
n/a
VEA24K 23000/22700 n/a 9.5/9.5 47" 23"
  • Unit Dimensions

    Height
    47"
    Width
    23"
    Depth
    23"

Detailed Electrical Information

Volts Rated
230/208
Cooling Amps
10.0/10.4
Amps (locked rotor)
34.8 amps
Amps (full load)
9.5 amps
Cooling Watts
2421/2389
Heating Amps
n/a
Heating Watts
n/a
Plug Face (NEMA #)
Power Cord Length
ft.
Air Circulation
610 cubic feet per minute
Est. Yearly Operating Costs
n/a
Moisture Removal
7.2 pints/hr
Net Weight
167 lbs
Shipping Weight
220 lbs
Suggested Retail Price
$4,756
Indoor CFM, High
n/a
Indoor CFM, Med
n/a
Indoor CFM, Low
610
VHA24K 23000/22800 20000/19500 9.1/9.1 47" 23"
  • Unit Dimensions

    Height
    47"
    Width
    23"
    Depth
    23"

Detailed Electrical Information

Volts Rated
230/208
Cooling Amps
10.6/10.9
Amps (locked rotor)
34.8 amps
Amps (full load)
9.5 amps
Cooling Watts
2527/2505
Heating Amps
8.5/9.4
Heating Watts
1953/1953
Plug Face (NEMA #)
Power Cord Length
ft.
Air Circulation
610 cubic feet per minute
Est. Yearly Operating Costs
n/a
Moisture Removal
7.2 pints/hr
Net Weight
167 lbs
Shipping Weight
220 lbs
Suggested Retail Price
$5,388
Indoor CFM, High
n/a
Indoor CFM, Med
n/a
Indoor CFM, Low
610