Full Range of Model Specifications.

Chill comes in a range of sizes and capacities. Click on the model number for detailed installation information. Take a look.

We’ve also included definitions of some common air conditioning terms. Contact us if you would like us to add one that we’ve missed.

Moisture Removal
Measured in pints per hour, this rates the air conditioner’s dehumidifying capability.
1.5–6.8 pints/24 hours
Air Circulation (CFM)
The amount of air that moves past a stationary point in one minute. Measured in cubic feet per minute.
140–590 ft3/min
Cooling Capacity
Air conditioner capacities are rated in Btu per hour. This is the measurement used to match your cooling or heating needs with an air conditioner. Btu stands for British Thermal Unit, which is the amount of heat needed to raise the temperature of one pound of water by one degree Fahrenheit.
5450–23500 Btu/hr
EER
The Energy Efficiency Ratio measures how efficiently an air conditioner will operate when the outdoor temperature is 95°. The ratio is calculated by dividing the cooling capacity (Btu/h) by the power needed to run the unit (watts). The higher the EER, the more efficient the air conditioner and the less costly it is to operate.
8.5–10.8

Individual Specifications

2012 Chill Models

Model Cooling Capacity
(Btu/hr)
Heating Capacity
(Btu/hr)
EER Energy Star Qualified Min. Extension Outside
CP05G10A 5450 n/a 10.7 10 3/4"
  • Unit Dimensions

    Height
    12"
    Width
    18 1/2"
    Depth
    15"
  • Window Dimensions

    Min. height
    Min. width
    20 1/8"
    Max. width
    36"
  • In-Wall Installation

    Opening height
    n/a
    Opening width
    n/a
    Max. wall depth
    n/a

Additional Measurement Information

Min. Extension Into Room
3 1/2"
Shell Depth to Louvers
5"
Sleeve
P1

Detailed Electrical Information

Voltage
115
Circuit Rating Breaker or T-D Fuse
125V-15A
Plug Face (NEMA #)
5-15P
Power Cord Length
6 ft.
Cooling Amps
4.8
Heating Amps
Air Circulation
140 cubic feet per minute
Est. Yearly Operating Costs
$40
Moisture Removal
1.5 pints/24 hours
Net Weight
46 lbs
Shipping Weight
50 lbs
Suggested Retail Price
$309
CP06G10A 6000 n/a 11.2 Yes 11"
  • Unit Dimensions

    Height
    14"
    Width
    18 3/8"
    Depth
    20 7/8"
  • Window Dimensions

    Min. height
    Min. width
    20 1/8"
    Max. width
    36"
  • In-Wall Installation

    Opening height
    14 1/8"
    Opening width
    18 7/8"
    Max. wall depth
    7 1/2"

Additional Measurement Information

Min. Extension Into Room
4 1/2"
Shell Depth to Louvers
8 1/8"
Sleeve
P6

Detailed Electrical Information

Voltage
115
Circuit Rating Breaker or T-D Fuse
125V-15A
Plug Face (NEMA #)
5-15P
Power Cord Length
6 ft.
Cooling Amps
5.1
Heating Amps
Air Circulation
200 cubic feet per minute
Est. Yearly Operating Costs
$45
Moisture Removal
1.8 pints/24 hours
Net Weight
60 lbs
Shipping Weight
66 lbs
Suggested Retail Price
$399
CP08G10A 7800 n/a 11.2 Yes 11"
  • Unit Dimensions

    Height
    14"
    Width
    18 3/8"
    Depth
    20 7/8"
  • Window Dimensions

    Min. height
    Min. width
    20 1/8"
    Max. width
    36"
  • In-Wall Installation

    Opening height
    14 1/8"
    Opening width
    18 7/8"
    Max. wall depth
    7 1/2"

Additional Measurement Information

Min. Extension Into Room
4 1/2"
Shell Depth to Louvers
8 1/8"
Sleeve
P6

Detailed Electrical Information

Voltage
115
Circuit Rating Breaker or T-D Fuse
125V-15A
Plug Face (NEMA #)
5-15P
Power Cord Length
6 ft.
Cooling Amps
6.8
Heating Amps
Air Circulation
250 cubic feet per minute
Est. Yearly Operating Costs
$58
Moisture Removal
2.2 pints/24 hours
Net Weight
64 lbs
Shipping Weight
70 lbs
Suggested Retail Price
$499
CP10G10A 10000 n/a 11.3 Yes 12"
  • Unit Dimensions

    Height
    15"
    Width
    23 5/8"
    Depth
    21 3/4"
  • Window Dimensions

    Min. height
    Min. width
    25 1/4"
    Max. width
    39"
  • In-Wall Installation

    Opening height
    15 1/4"
    Opening width
    23 7/8"
    Max. wall depth
    8"

Additional Measurement Information

Min. Extension Into Room
4 1/2"
Shell Depth to Louvers
8 3/4"
Sleeve
P7

Detailed Electrical Information

Voltage
125V-15A
Circuit Rating Breaker or T-D Fuse
5-15P
Plug Face (NEMA #)
5-15P
Power Cord Length
6 ft.
Cooling Amps
8.5
Heating Amps
Air Circulation
300 cubic feet per minute
Est. Yearly Operating Costs
$73
Moisture Removal
3.0 pints/24 hours
Net Weight
81 lbs
Shipping Weight
87 lbs
Suggested Retail Price
$599
CP12G10A 12000 n/a 11.3 Yes 12"
  • Unit Dimensions

    Height
    15"
    Width
    23 5/8"
    Depth
    21 3/4"
  • Window Dimensions

    Min. height
    Min. width
    25 1/4"
    Max. width
    39"
  • In-Wall Installation

    Opening height
    15 1/4"
    Opening width
    23 7/8"
    Max. wall depth
    8"

Additional Measurement Information

Min. Extension Into Room
4 1/2"
Shell Depth to Louvers
8 3/4"
Sleeve
P7

Detailed Electrical Information

Voltage
125V-15A
Circuit Rating Breaker or T-D Fuse
5-15P
Plug Face (NEMA #)
5-15P
Power Cord Length
6 ft.
Cooling Amps
10.2
Heating Amps
Air Circulation
330 cubic feet per minute
Est. Yearly Operating Costs
$89
Moisture Removal
3.3 pints/24 hours
Net Weight
87 lbs
Shipping Weight
93 lbs
Suggested Retail Price
$679
CP15G10A 15000 n/a 11.2 Yes 16 5/8"
  • Unit Dimensions

    Height
    16 7/8"
    Width
    26"
    Depth
    27 7/8"
  • Window Dimensions

    Min. height
    Min. width
    26 1/2"
    Max. width
    42"
  • In-Wall Installation

    Opening height
    17 1/8"
    Opening width
    26 1/4"
    Max. wall depth
    9"

Additional Measurement Information

Min. Extension Into Room
5 1/2"
Shell Depth to Louvers
10 1/4"
Sleeve
P8

Detailed Electrical Information

Voltage
115
Circuit Rating Breaker or T-D Fuse
125V-15A
Plug Face (NEMA #)
5-15P
Power Cord Length
6 ft.
Cooling Amps
12.9
Heating Amps
Air Circulation
400 cubic feet per minute
Est. Yearly Operating Costs
$112
Moisture Removal
4.0 pints/24 hours
Net Weight
120 lbs
Shipping Weight
134 lbs
Suggested Retail Price
$829
CP24G30A 23500/23000 n/a 9.8/9.8 Yes 19 1/2"
  • Unit Dimensions

    Height
    16 7/8"
    Width
    26"
    Depth
    30 3/8"
  • Window Dimensions

    Min. height
    Min. width
    26 1/2"
    Max. width
    42"
  • In-Wall Installation

    Opening height
    17 1/8"
    Opening width
    26 1/4"
    Max. wall depth
    9"

Additional Measurement Information

Min. Extension Into Room
5 1/2"
Shell Depth to Louvers
10 1/4"
Sleeve
P9

Detailed Electrical Information

Voltage
230/208
Circuit Rating Breaker or T-D Fuse
250V-20A
Plug Face (NEMA #)
6-20P
Power Cord Length
4 ft.
Cooling Amps
11.4/12.4
Heating Amps
Air Circulation
590 cubic feet per minute
Est. Yearly Operating Costs
$196
Moisture Removal
6.8 pints/24 hours
Net Weight
146 lbs
Shipping Weight
160 lbs
Suggested Retail Price
$1,049

2012 Chill+ Electric Heater Models

Model Cooling Capacity
(Btu/hr)
Heating Capacity
(Btu/hr)
EER Energy Star Qualified Min. Extension Outside
EP08G11A 8000 3850 9.8 12"
  • Unit Dimensions

    Height
    15"
    Width
    23 5/8"
    Depth
    21 3/4"
  • Window Dimensions

    Min. height
    Min. width
    25 1/4"
    Max. width
    39"
  • In-Wall Installation

    Opening height
    15 1/4"
    Opening width
    23 7/8"
    Max. wall depth
    8"

Additional Measurement Information

Min. Extension Into Room
Shell Depth to Louvers
Sleeve
P7

Detailed Electrical Information

Voltage
115/60/1
Circuit Rating Breaker or T-D Fuse
125V-15A
Plug Face (NEMA #)
5-15P
Power Cord Length
6 ft.
Cooling Amps
7.5
Heating Amps
11.0
Air Circulation
265 cubic feet per minute
Est. Yearly Operating Costs
$65
Moisture Removal
2.6 pints/24 hours
Net Weight
79 lbs
Shipping Weight
85 lbs
Suggested Retail Price
$619
EP12G33A 12000/11500 11200/9200 9.8/9.8 12"
  • Unit Dimensions

    Height
    15"
    Width
    23 5/8"
    Depth
    21 3/4"
  • Window Dimensions

    Min. height
    Min. width
    25 1/4"
    Max. width
    39"
  • In-Wall Installation

    Opening height
    15 1/4"
    Opening width
    23 7/8"
    Max. wall depth
    8"

Additional Measurement Information

Min. Extension Into Room
Shell Depth to Louvers
Sleeve
P7

Detailed Electrical Information

Voltage
230/208
Circuit Rating Breaker or T-D Fuse
250V-20A
Plug Face (NEMA #)
6-20P
Power Cord Length
4 ft.
Cooling Amps
5.5/5.8
Heating Amps
15.3/14.0
Air Circulation
265 cubic feet per minute
Est. Yearly Operating Costs
$97
Moisture Removal
3.3 pints/24 hours
Net Weight
87 lbs
Shipping Weight
93 lbs
Suggested Retail Price
$769
EP18G33A 18000/17500 12000/9800 9.7/9.7 19 1/2"
  • Unit Dimensions

    Height
    16 7/8"
    Width
    26"
    Depth
    30 3/8"
  • Window Dimensions

    Min. height
    Min. width
    26 1/2"
    Max. width
    42"
  • In-Wall Installation

    Opening height
    17 1/8"
    Opening width
    26 1/4"
    Max. wall depth
    9"

Additional Measurement Information

Min. Extension Into Room
Shell Depth to Louvers
Sleeve
P9

Detailed Electrical Information

Voltage
230/208
Circuit Rating Breaker or T-D Fuse
250V-20A
Plug Face (NEMA #)
6-20P
Power Cord Length
4 ft.
Cooling Amps
8.3/9.0
Heating Amps
15.0/16.0
Air Circulation
430 cubic feet per minute
Est. Yearly Operating Costs
$148
Moisture Removal
5.5 pints/24 hours
Net Weight
136 lbs
Shipping Weight
150 lbs
Suggested Retail Price
$999
EP24G33A 23500/23000 12000/9800 8.5/8.5 19 1/2"
  • Unit Dimensions

    Height
    16 7/8"
    Width
    26"
    Depth
    30 3/8"
  • Window Dimensions

    Min. height
    Min. width
    26 1/2"
    Max. width
    42"
  • In-Wall Installation

    Opening height
    17 1/8"
    Opening width
    26 1/4"
    Max. wall depth
    9"

Additional Measurement Information

Min. Extension Into Room
Shell Depth to Louvers
Sleeve
P9

Detailed Electrical Information

Voltage
230/208
Circuit Rating Breaker or T-D Fuse
250V-20A
Plug Face (NEMA #)
6-20P
Power Cord Length
4 ft.
Cooling Amps
12.2/13.2
Heating Amps
15.0/16.0
Air Circulation
560 cubic feet per minute
Est. Yearly Operating Costs
$220
Moisture Removal
6.5 pints/24 hours
Net Weight
146 lbs
Shipping Weight
160 lbs
Suggested Retail Price
$1,149